Bryant furnace code 13 - 2003 Bryant Furnace, after doing a reset by opening the bottom panel and re-installing bottom panel, it will successfully start up and the igniter will glow and blue flames heat up the house.. but aft …

 
01 - Bryant Furnace Igniter. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter fails or cracks, the furnace won’t heat. To determine if the igniter is faulty, remove the igniter and inspect it for cracks. If the igniter is cracked, replace it. If the igniter is not cracked, use a multimeter to test the .... Bright start daycare

Carrier furnace fault code 13 limit lockout can be a frustrating and intimidating problem to troubleshoot. However, with the right steps, you can successfully troubleshoot the issue on your own. In this blog, we’ve provided you with a step-by-step guide to troubleshooting Carrier furnace fault code 13 limit lockout as well as some tips for ...Find a Trusted Bryant Dealer to Handle Your Heating & Cooling Services. As Bryant Dealers, these technicians are qualified in a broad range of award-winning furnaces, air conditioners, heat pumps, ductless units, geothermal systems, and more. Along with superior management of temperature, we offer a range of effective air quality … Over-riding the thermostat up to a warmer temp doesn't cause the furnace to turn back on. The thermostat/controller is the Bryant Evolution. It's pretty complicated so maybe we've screwed up a setting somewhere. Thanks in advance for any help you might provide. Mike. Reply. 11-30-2015, 09:06 PM #2. Mr Bill. The news from your HVAC repairman that you need a new furnace is definitely not a welcome experience. Use this guide to find the top reviewed Bryant furnaces when replacing your fu...With SEER ratings up to 16, the Bryant ® Preferred Series of packaged HVAC systems works overtime for whole-home comfort. The quiet, efficient operation of the Preferred Series is available in models ranging from a gas heat/electric cool model to a heat pump system and air conditioner. These are the top-of-the-line packaged systems from Bryant.Bryant furnace. It locks out with code 13. 1 year, code 13. Every 4-5 hours for a couple days since temperature dropped below zero. I have open more vents (basement area and rooms directly above furnace that I don't generally need heated) to try to release more heat and get better airflow. It seems to have worked slightly but it locked out ... Found this old post and gave the same thing a try after my Bryant was cycling 3-3, 3-1 for a couple of days. I removed the upper limit switch in the middle back wall of the furnace, gave it a couple of light wacks with a wrench, and put it back in. You may use the warranty information provided here when contacting a contractor to learn more about your coverage, or contact customer care at 1-800-428-4326 to ask questions about your policy.My bryant gas heater is displaying a code 13 limit switch lockout and after 3 hours and the manual reset has been activated it comes on and works till the thermostat …Carrier 9200 code 13 induction motor replacementWhen you have questions, you can depend on Bryant to be ready and able to answer. We're committed to educating our customers and being available to help in any way possible. You can always contact your local Bryant ® contractor or get in touch with us for help. But first, take a look at a few of the questions other Bryant customers often have ...Welcome to HVAC-Talk.com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R.6 posts · Joined 2018. #1 · Nov 9, 2018. Hi guys, new member here and I'm so glad i found this forum. I am getting a code 13 (limit circuit lockout) on my carrier 58PAV070-08 This is after replacing both the limit switch and the roll out switch! I have tried letting it run for the 3 hour reset and resetting the roll out switch manually with ...The standard price of a Bryant Furnace can be about $2300. Although some of the units that Bryant produces can be more expensive as compared to others, it all depends on the size and features that you want. The typical range that the furnaces can lie between is $800-$2450, with separate costs for installation.Clean Or Replace The Air Filters. One of the most common causes of code 13 is a blocked air filter or vent. If your air filters are dirty or clogged, it can restrict the airflow through the furnace and cause it to overheat. To fix this issue, you can try cleaning the air filters or replacing them with new ones.pressure switch pressure low ... We were constantly getting these "SYSTEM FAULT 13 - Limit Lockout" messages. I would turn off the thermostat and turn it back on and it would work for an hour and then the error would return. My contractor fired the sub and hired another Bryant installer to fix the issues. The Evolution air purifier achieves a MERV 15 rating based on third-party testing (2012) showing 95% of particles size 1.0 to 3.0 microns captured and 85% of particles size 0.3 to 1.0 microns captured. 1 Compared to a hold of 72°F/22°C. Bryant Heating & Cooling offers heating and air conditioning systems to meet your needs. Mar 17, 2020 · Code Description Information; 11: NO PREVIOUS CODE: Stored status codes are erased when 115V or 24V power to the control is interrupted or after 48Hrs. 12: BLOWER ON AFTER POWER-UP: Blower run for 90 seconds if the unit is powered-up during a call for heat. 13: LIMIT OR ROLLOUT LOCKOUT: Control will reset after three hours. Refer to #33: 14 ... I have cleared the exhaust port on both ends and replaced filter, and found through trial and error, that if I leave the covers off the front and clamp the black button in the on position, the furnace works like a charm. As soon as I put the covers back on, it won't cycle through with a resulting code 31. Any help greatly appreciated.Carrier 90% Gas Furnace: 350MAV. Re: Flashing Code 14 / Fault Code 14. Code 14 = Four Failed Ignition Attempts. Diagnostic Light Sequence: 1-Short Flash, 4-Long Flashes (- , — — — —) Very Important! If the inducer motor is off during lockout, this indicates that flame failed to establish 4 times.Bryant furnace. It locks out with code 13. 1 year, code 13. Every 4-5 hours for a couple days since temperature dropped below zero. I have open more vents (basement area and rooms directly above furnace that I don't generally need heated) to try to release more heat and get better airflow. It seems to have worked slightly but it locked out ...Each of the following status codes is a two digit number with the first digit determined by number of flashes of the yellow led and the second digit determin...1. Flash code 31 (3 short flashes/ 1 long) within a short period of time. 2. Inducer motor does not start. 3. HPS has 24 VAC on one side and is open on the other. I think the inducer motor is fine for if I cycle the 110VAC power it …Features. Experience exceptional heating efficiency: up to 96.7% AFUE. Enjoy the ultra-quiet performance and even-temperature comfort of variable 25-speed air delivery. It's a great choice for improving cooling efficiency, or SEER2, and summertime humidity control.RESULT: LIMIT CIRCUIT FAULT FIX: Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual … The Evolution air purifier achieves a MERV 15 rating based on third-party testing (2012) showing 95% of particles size 1.0 to 3.0 microns captured and 85% of particles size 0.3 to 1.0 microns captured. 1 Compared to a hold of 72°F/22°C. Bryant Heating & Cooling offers heating and air conditioning systems to meet your needs. Bryant started more than a century ago in 1904. Now, the company offers high-quality gas furnaces with low sound and high AFUE ratings of up to 98.3%. The company aims to offer innovative packaged systems. For example, its Bryant Hybrid Heat system combines a gas furnace and heat pump into one heating and cooling system.Code Description Information; 11: NO PREVIOUS CODE: Stored status codes are erased when 115V or 24V power to the control is interrupted or after 48Hrs. 12: BLOWER ON AFTER POWER-UP: Blower run for 90 seconds if the unit is powered-up during a call for heat. 13: LIMIT OR ROLLOUT LOCKOUT: Control will reset after three …Recent Posts. Importance of Choosing the Right Commercial HVAC System; Dryer Vent Cleaning: Ensuring Efficiency and Safety; The Comprehensive Guide to Air Duct Cleaning Services and Furnace Duct CleaningJanuary 18, 2024. Is there something wrong with your Bryant furnace? Table of Contents. The Complete List of Bryant Furnace Error Codes. Red LED1 On. Red LED2 On. Yellow LED3 On. Green LED4 On. Red …The 13 error code of your Bryant Furnace furnace is a problem with the airflow. It can cause overheating, fire, explosion, or other serious problems. Learn how to fix it by …Are you looking to give your home a fresh new look? Look no further than the Bryant Lane Home Catalog. With its wide range of high-quality furniture and decor options, this catalog...Here are some common methods used to reset Bryant furnace codes:Using the SW-1 Button:a. Locate the control board on your Bryant furnace.b. Identify the SW-1 button, usually found on the control board.c. Press and release the SW-1 button.d. Wait for a few seconds to allow the reset process to complete.e.Bryant furnace 8 years old contractor did not register, out of warranty, 355AAV060100, code 33 changes to code 13. high limit open closes when suck on hose, unit stays in low heat. vent blowers sounds …Bryant started more than a century ago in 1904. Now, the company offers high-quality gas furnaces with low sound and high AFUE ratings of up to 98.3%. The company aims to offer innovative packaged systems. For example, its Bryant Hybrid Heat system combines a gas furnace and heat pump into one heating and cooling system.Find the most common problems that can cause a Bryant Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Track Order. Log in or sign up ... Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment ...Error code 13 on a Bryant furnace typically indicates a limit switch lockout. This can result from various issues such as a dirty air filter, a blocked vent, or a …May 4, 2022 · Call them back and insist they send a technician that knows what they are doing. Code 13 has nothing to do with the condensate. Those tubes need to be corrected, then troubleshooting done to determine why the furnace is locking out on 13. Climate Control Solutions for your Home or Office. If you're looking for help fixing your Bryant Furnace, look no further! Our comprehensive Bryant Furnace error code guide will explain common issues, provide...Carrier 90% Gas Furnace: 350MAV. Re: Flashing Code 31 / Fault Code 31. Diagnostic Light Sequence: 3-Short Flashes, 1-Long Flash (- - - , —) On Carrier 90% Furnaces, the Pressure switch may be wired in series with a Low Gas Pressure Switch. Therefore, a Fault Code 31 is caused by one of the following: The Bryant plus 90 furnace has an automatic reset feature that can be used if the error code persists. While there is no one answer to how to fix this error, Gas and Oil Home Heating Furnaces - Bryant Furnace issues - codes 13 and 33 - My 14-yo furnace has been working fine until recently. It stopped heating, saw code 33, had a handyman friend who does have HVAC experience check it out, cleaned out some things, did some routine maintenance. The “clicking” noise would not goHow long does it take to become elite at your craft? And what do the people who master their goals do differently than the rest of us? That’s what John Hayes, a cognitive psycholog...Bryant furnace. It locks out with code 13. 1 year, code 13. Every 4-5 hours for a couple days since temperature dropped below zero. I have open more vents (basement area and rooms directly above furnace that I don't generally need heated) to try to release more heat and get better airflow. It seems to have worked slightly but it locked out ... Find the most common problems that can cause a Bryant Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 ... If you own a Rheem furnace, you may have noticed that it has a blinking light on the control board. These blinking lights are actually diagnostic codes that can help you identify p...Helpful Resources for Bryant. Owners. In addition to quality service from a Bryant dealer, Bryant heating and cooling systems come with access to all the useful product information and documentation you need. Here you’ll find product documents, troubleshooting resources and more, in addition to links for registering your products or …Dec 10, 2022 · Code 13, normally occurs as a result of code 33. In most cases, you will first spot code 33 which will stay for a while before turning to code 13. Code 33 on Carrier and Bryant furnaces is caused by a lack of airflow. If the issue is not resolved in time, it may develop to code 13, caused by safety lockout. Code 33 is a Limit Circuit Fault code. Aug 19, 2023 · A carrier furnace code 13 indicates that the limit switch is open. If the limit switch opens 5 times for at least 3 minutes each time during 1 thermostat cycle this will trigger the status code 13. This status code is associated with overheating within the furnace causing the limit switch to open. With that said, there are a few things that can ... The code 31 on a Bryant furnace also refers to a pressure switch issue. This code suggests problems with the venting system, pressure switch, or inducer motor like Carrier furnaces. Seeking professional assistance is advised for proper troubleshooting and repair. What is the code 1 3 on a Carrier furnace? A code 13 on a Carrier furnace …January 18, 2024. Is there something wrong with your Bryant furnace? Table of Contents. The Complete List of Bryant Furnace Error Codes. Red LED1 On. Red LED2 On. Yellow LED3 On. Green LED4 On. Red …we have a Carrier 58mya080 furnace serial #0398a003a get codes 12 and 13. At call for heat, pre blower comes on for 90 seconds, no gas, no ignition, ... My Bryant furnace is not putting out warm air. I just went and looked at …Bryant furnaces are manufactured in Indianapolis, Indiana; it’s a state-of-the-art facility that’s one of our flagship plants and home to our North American ...The government's $1500 tax credit makes it a great time to update a lackluster heating system. Make sure to get the $1500 and then some by using this step-by-step guide upgrading y...26 Jan 2024 ... Gas furnace repair led light code 13 Are you experiencing issues with your gas furnace not blowing heat? In this informative video, ...Our Preferred Value for Efficient Heating Comfort. Get comfortable this winter with savings you can depend on. The Model 922S is an economical choice for efficient gas heating and comfort-enhancing humidity control during the hot, summer months. AFUE Efficiency : up to 92.1%. Gas Valve Type : Single-Stage. FIND A DEALER.The lowest efficiency allowed by law for new gas furnaces is 78 percent, and some new models achieve 97 percent, near-total efficiency. The price of a furnace generally rises in step with its fuel ...3 fast blips and one longer one is 31 not 13, 31 is a pressure switch problem. It isnt closing and current isnt passing through. You need to check the pressure switch, the hose and …A person can read Trane furnace codes by looking at sites such as FurnaceReviews.net. A Trane furnace shows the owner that there is an issue within the furnace by using a red blink...33. LIMIT CIRCUIT FAULT – Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset.The standard price of a Bryant Furnace can be about $2300. Although some of the units that Bryant produces can be more expensive as compared to others, it all depends on the size and features that you want. The typical range that the furnaces can lie between is $800-$2450, with separate costs for installation.In this HVAC Training Video, I Show How to Troubleshoot Gas Furnace LED Error Code Problems. I Discuss What these Status Codes Mean and How to Test the Furna...Nov 9, 2013 · Bryant furnace 340series code 13/33. Hello, My furnace keeps flashing codes 13/33 limit lockout. I checked for a restriction and found rocks and mulch in the pvc piping so I cleaned it out and it ran 1 cycle without code then started flashing code again so I cleaned the flame rod and it did the same thing 1 cycle then code. A single blink of the yellow light typically indicates a minor issue, such as a dirty air filter or a closed vent. Begin troubleshooting by checking the air filter and …Learn how to install, operate and maintain the Bryant 340AAV condensing gas furnace with this detailed manual. This furnace features a four-pass heat exchanger, a hot surface ignition system and a variable speed blower motor. Find out how to troubleshoot common problems and ensure optimal performance.Turn off your furnace before beginning any inspection. Locate the ignition control board, which is often the main culprit for the LED blinking 3 times. Inspect the board for any signs of damage or wear, including loose connections or blackened areas. Clean the board carefully using a dry cloth or compressed air.Here are some common methods used to reset Bryant furnace codes:Using the SW-1 Button:a. Locate the control board on your Bryant furnace.b. Identify the SW-1 button, usually found on the control board.c. Press and release the SW-1 button.d. Wait for a few seconds to allow the reset process to complete.e.Jan 30, 2024 · On Carrier, Bryant and Payne furnaces, the lack of airflow will cause an error 33, and sometimes lead to error 13 due to safety lockout. Error 33 is a Limit Circuit Fault. It means that the high limit or flame rollout switch is open. This can lead to error code 13, Limit Circuit Lockout. A dirty or clogged air filter is a frequent cause of overheating and can activate code 33 in Bryant furnaces. If your furnace displays code 33, the initial step to take is examining the air filter. Locate the air filter near the blower compartment and assess its condition. If it appears dirty or if more than 2 months have passed since the last ...In this HVAC Training Video, I Show How to Troubleshoot Gas Furnace LED Error Code Problems. I Discuss What these Status Codes Mean and How to Test the Furna...2023 Minimum Efficiency Standards. These new government regulations apply to all manufacturers in the HVAC industry. For air conditioners, the Department of Energy’s new minimum efficiency standards will vary by region, so your choice of AC units will depend on where you live. For heat pumps, the new standard will be uniform across the nation.RESULT: LIMIT CIRCUIT FAULT FIX: Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual …HomeAdvisor says Bryant furnaces cost about $1,500-4,500. This mid-range Bryant furnace line ranges $2,500-3,500. Prices vary based on the model, your location, and your furnace dealer. Additionally, you’ll pay for installation. HomeAdvisor says this ranges from $500 to $2,500. Bryant furnace warranty. Bryant furnaces have a 10-year standard ...2003 Bryant Furnace, after doing a reset by opening the bottom panel and re-installing bottom panel, it will successfully start up and the igniter will glow and blue flames heat up the house.. but aft …Feb 18, 2021 · Carrier Gas Furnace: 58MXA. Re: Flashing Code 13 / Fault Code 13. Code 13 =Limit or Flame Roll-Out Lockout. Diagnostic Light Sequence: 1-Short Flash, 3-Long Flashes (- , — — — ) Limit circuit open for more than 3 minutes Auto-Reset after 3 Hours If your furnace light is blinking 3 times, it could indicate an issue. While Codes 31, 33 & 13 are the most common, here are some additional causes of a Carrier furnace blinking yellow light: Problem A: Low-pressure switch fault. Problem B: Blower motor malfunctions. Problem C: Reversed line voltage polarity. With SEER ratings up to 16, the Bryant ® Preferred Series of packaged HVAC systems works overtime for whole-home comfort. The quiet, efficient operation of the Preferred Series is available in models ranging from a gas heat/electric cool model to a heat pump system and air conditioner. These are the top-of-the-line packaged systems from Bryant. Leraned its a code 13. 2. Crazy dirty filter - I changed it - stupid on my part for letting it go so long. Maybe the orginal source of the problem. 3. Cleaned the flame senor with 400 gr sand papper. 4. Went through the steps as per manual to re start furnace. Still blowing cold air and not burners turning on.Carrier 90% Gas Furnace: 350MAV. Re: Flashing Code 31 / Fault Code 31. Diagnostic Light Sequence: 3-Short Flashes, 1-Long Flash (- - - , —) On Carrier 90% Furnaces, the Pressure switch may be wired in series with a Low Gas Pressure Switch. Therefore, a Fault Code 31 is caused by one of the following:A single blink of the yellow light typically indicates a minor issue, such as a dirty air filter or a closed vent. Begin troubleshooting by checking the air filter and … This is Bryant furnace error code 13. The furnace’s red light will be on and the heating system won't be working. we have a Carrier 58mya080 furnace serial #0398a003a get codes 12 and 13. At call for heat, pre blower comes on for 90 seconds, no gas, no ignition, ... My Bryant furnace is not putting out warm air. I just went and looked at …Features. Experience exceptional heating efficiency: up to 96.7% AFUE. Enjoy the ultra-quiet performance and even-temperature comfort of variable 25-speed air delivery. It's a great choice for improving cooling efficiency, or SEER2, and summertime humidity control.The 13 error code of your Bryant Furnace furnace is a problem with the airflow. It can cause overheating, fire, explosion, or other serious problems. Learn how to fix it by …17 Dec 2015 ... I don't know what to do about Carrier and Bryant Furnace Error Code ... ? I know error code 13 is the error for the ... Carrier and Bryant Furnace ... Find the most common problems that can cause a Bryant Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 ... If you get a Bryant Furnace error code 13, it means that your furnace is not working. To find the cause of the problem, we need to know more about yourJan 4, 2018 · You have continues blower motor running no power to the inducer and you're getting a error code 33 which is limit circuit fault and then it goes into code 13...

SEGALL BRYANT & HAMILL EMERGING MARKETS FUND RETAIL CLASS- Performance charts including intraday, historical charts and prices and keydata. Indices Commodities Currencies Stocks. Indian food sacramento

bryant furnace code 13

Feb 18, 2021 · Carrier 90% Gas Furnace: 350MAV. Re: Flashing Code 13 / Fault Code 13. Code 13 =Limit or Flame Roll-Out Lockout. Diagnostic Light Sequence: 1-Short Flash, 3-Long Flashes (- , — — — ) Limit circuit open for more than 3 minutes Auto-Reset after 3 Hours On Carrier, Bryant and Payne furnaces, the lack of airflow will cause an error 33, and sometimes lead to error 13 due to safety lockout. Error 33 is a Limit Circuit Fault. It means that the high …Our Preferred Value for Efficient Heating Comfort. Get comfortable this winter with savings you can depend on. The Model 922S is an economical choice for efficient gas heating and comfort-enhancing humidity control during the hot, summer months. AFUE Efficiency : up to 92.1%. Gas Valve Type : Single-Stage. FIND A DEALER.1. Flash code 31 (3 short flashes/ 1 long) within a short period of time. 2. Inducer motor does not start. 3. HPS has 24 VAC on one side and is open on the other. I think the inducer motor is fine for if I cycle the 110VAC power it …Feb 18, 2021 · Carrier Gas Furnace: 58MXA. Re: Flashing Code 13 / Fault Code 13. Code 13 =Limit or Flame Roll-Out Lockout. Diagnostic Light Sequence: 1-Short Flash, 3-Long Flashes (- , — — — ) Limit circuit open for more than 3 minutes Auto-Reset after 3 Hours When you look at the piece you need to take the hose off, remove the two wires attached to the back, and remove the screws that hold it into the side of the furnace's metal. Grab your new sensor and screw it in. You'll need to check the back of the sensor to see which plug is positive and negative, and that's about the extent of the difficulty ...Jan 18, 2024 · Check the wiring to the motor, if this code appears together with code 4-1. In all the other cases, make sure that the ductwork is not undersized , that the registers aren’t closed , and that the filters are clean . READ: How to Troubleshoot Bryant Furnace Yellow Light Codes. Frequently Asked Questions for Byrant Furnace Q. What is the 13 code for a Bryant furnace? A. Code 13 on a Bryant furnace indicates a limit circuit lockout, which may suggest that your furnace is overheating. This could be due to a dirty air filter or a … With SEER ratings up to 16, the Bryant ® Preferred Series of packaged HVAC systems works overtime for whole-home comfort. The quiet, efficient operation of the Preferred Series is available in models ranging from a gas heat/electric cool model to a heat pump system and air conditioner. These are the top-of-the-line packaged systems from Bryant. Recent Posts. Importance of Choosing the Right Commercial HVAC System; Dryer Vent Cleaning: Ensuring Efficiency and Safety; The Comprehensive Guide to Air Duct Cleaning Services and Furnace Duct CleaningThe 310AAV/310JAV 4- -Way Multipoise Gas Furnace was. designed by Bryant dealers for Bryant dealers. Applications are. easy with 4- -way Multipoise design, through- -the- -furnace. downflow venting, 13 different venting options, and a design for. easy service access. An inner blower door is provided for tighter.The standard price of a Bryant Furnace can be about $2300. Although some of the units that Bryant produces can be more expensive as compared to others, it all depends on the size and features that you want. The typical range that the furnaces can lie between is $800-$2450, with separate costs for installation. Bryant 340MAV Limit Switch lockout help. I am selling my Condo and it has sat vacant for 6 weeks since I moved out. I got a notification from my thermostat that it lost connectivity. I head over here and the code was 13 Limit Switch Lockout. I flip the furnace off and I checked the 1" filter, it is dirtier than hell. 2 To the original owner, when product is used in an owner-occupied residence, a 10-year parts limited warranty upon timely registration of your new equipment. Warranty period is 5 years if not registered within 90 days. Jurisdictions where warranty benefits cannot be conditioned on registration will automatically receive a 10-year parts limited warranty.Jan 13, 2020 · Bryant Furnace Status Code 13/ 33 /31. Hi, Our furnace decided to go wonky on us this morning, as it was chilly in the house and our Ecobee was off. When I checked the furnace, it was giving me the status code of 13 / 31 / 33. According to articles online, its telling me to replace the limit switch. Is your Rheem furnace acting up? Before calling a technician, you can try troubleshooting the issue yourself by decoding the blinking light codes on your furnace. Rheem furnaces ar... 13 is limit circuit lockout, in which case your furnace would try and restart after 3 hours. The limit circuit is there to protect the furnace from overheating if there is insufficient airflow through the heat exchanger taking the heat away from the furnace and pushing it into your ductwork. A single blink of the yellow light typically indicates a minor issue, such as a dirty air filter or a closed vent. Begin troubleshooting by checking the air filter and …0:00 / 1:12. Bryant Furnace Fault Codes. Tradesman Mechanical Services Ltd. If you're looking for help fixing your Bryant Furnace, look no further! Our comprehensive Bryant ….